Sign In | Join Free | My bjjsgy.com
China Jiangsu Olymspan Thermal Energy Equipment Co.,Ltd logo
Jiangsu Olymspan Thermal Energy Equipment Co.,Ltd
Active Member

8 Years

Home > Thermal oil circulating pump >

WRY100-65-230 Thermal oil circulating pump

Jiangsu Olymspan Thermal Energy Equipment Co.,Ltd

WRY100-65-230 Thermal oil circulating pump

Place of Origin : Changzhou China

Brand Name : WULIN

Certification : GB

Model Number : WRY100-65-230

MOQ : 1set

Price : $5000-$50000

Packaging Details : BOX

Delivery Time : 7days

Payment Terms : T/T in advance

Supply Ability : 500set/month

Contact Now

Usage of WRY conductive oil pump
It is widely used in many industries like oil, construction, spinning and so on. It is mainly used to transport the slightly corrosive hot liquids without solids in it. The working temperature will be ≤350℃.
Structure features
1. Introducing the overseas technologies and doing research and development, we come out with this second generation product.
2. With the double ball bearing being the supporting structure, we add lubricant to the front part of the pump and grease to the back of it. We set a oil pipeline in the middle part of it to check the sealing situation and the recycling of the conductive oil.
3. The heat will be radiated naturally and unlike the traditional water cooling structure, its structure is simpler and the volume is small. The running cost is cheap and its performance is good. The equipment is reliable and safe.
4. WRY series products are made of Teflon materials which have good adaptability to heat. Thus, it can maintain good sealing property under high temperature.
The installation and the inspection of the equipment unit
The installation and the inspection of the equipment unit
1.The life span and the proper operation of the pump is much affected by the installation of the pump. Thus it’s important to carefully install it.
2.The height, the length and the diameter of the pump shall be calculated before. And shorter is better.
3.There must be support for the outlet and the inlet of the pipes. We can’t place pipe’s load on the pump;
4.Choose a vast place to install the pump to convenient the maintenance and inspection and the heat dissipation.
5.Installation order:
(1) place the unit on the foundation constructed before;
(2) Loosen the coupling and place the level on the pump shaft and on the foundation. Adjust it to horizontal level and then tighten the bolt.
(3) Fill in the concrete to the foundation and the bolt hole.
(4) After the concrete is dried, check to see id there’s any loose. If not tighten the bolt on the ground.
(5) Adjust the level of the pump shaft and the motor shaft. The circular runout shall not be more than 0.1mm. the interval between two couplings shall be 2-3mm. When carrying out the inspection of the couplings, the circular run-out shall not be more than 0.1mm either. We adjust the motor to the pump and we can add fat mat to make the level even.
(6) Connect the pipelines and decide the rotating direction of the motor, then we shall connect the coupling and finally check the coaxiality of excircle.
Maintenance of the oil pump:
After install the pipes and the pump, we shall close the valve. Then we can do the pressure test to ensure that the sealing is good enough and there won’t be any leakage.
1 Preparations before the operation:
(1) Clean the site and loosen the bolt. Add the conductive oil. If the pump is over 110KW, we shall fill in the oil from one side till it spills from other side. Touch the coupling during the filling procedure and tighten the bolt till there’s no bubble.
(2) Check the rotating direction of the motor to see if it is the same as that of the pump.
(3) the coupling pump shall be rotated flexibly by hands.
(4) Fill the pump with the conductive oil to get rid of the air. The R sluice valve shall be closed.
(5) The conductive oil shall be heated at the beginning. The pre-heating will be done by the pump. Severe shake shall be avoided. We must stop to check if there’s any emergency.
Standard for the pre-heating treatment: the temperature of the pump shell shall be lower than 40°C. the speed shall be 50°C /hour. We shall loosen the bolt to 0.3-0.5 mm when pre-heat it and remember to tighten the bolt after the treatment.
(6)Before we start, we shall check to see if there’s any looseness in the foundation and in the bolt as well as the sealing situation.
2. Start
(1) Thoroughly check if the preparation work has been done.
(2) Turn on switches of meters
(3) Power-on. When the pump reaches the normal speed and the figures shown on the gage is proper, we shall open the sluice valve gradually and adjust to the needed conditions. The working time shall not exceed 3 min when the sluice valve is closed.

Model

traffic
m3/h

lift
m

speed
r/min

KW power

The efficiency of
n%

Cavitation allowance
m

Shaft power

With power

26-20-100

4.5

15

2825

0.45

0.75

40

0.8

50-32-150

8

22

2840

1.0

1.5

42

1.6

50-32-160

10

25

2840

1.5

2.2

42

1.8

65-40-160

12.5

25

2880

2.5

3

45

2.2

50-50-170

12.5

32

2890

3.2

4

45

2.5

65-40-190

18

40

2890

4.5

5.5

52

2.8

65-50-180

32

32

2900

4.5

5.5

52

2.7

65-50-170

40

25

2900

4.5

5.5

52

2.7

65-50-150

52

16

2900

4.2

5.5

52

2.8

65-40-200

25

50

2900

6.7

7.5

63

3.1

80-50-180

40

40

2900

6.7

7.5

63

3.1

80-50-170

60

20

2900

6.7

7.5

63

3.1

100-65-190

60

38

2930

9.2

11

68

3.5

100-65-200

80

40

2930

12.5

15

70

3.5

100-65-220

58

50

2930

12.5

15

68

3.5

100-65-210

90

45

2930

15.7

18.5

70

3.6

100-65-230

58

60

2930

15.5

18.5

62

3.5

100-65-230

100

55

2940

19.5

22

70

3.6

125-100-190

155

30

2930

17.6

22

72

3.8

100-65-240

100

70

2950

25.5

30

69.8

4.1

100-65-257

100

80

2950

32.5

37

67

3.6

125-100-220

160

45

2950

25.5

37

75

3.6

125-80-250

160

60

2970

35.5

45

74

5

125-80-270

150

85

2970

46

55

73

5

125-100-250

200

60

2970

42.8

55

76.8

6

125-100-257

260

70

2970

64.3

75

77

6.8

125-100-265

200

80

2970

59

75

74

6

125-100-245

300

55

2970

61

75

74

7.5

125-100-260

300

70

2970

75.3

90

78.2

8

125-100-270

220

85

2970

68

90

76

6

125-100-280

260

85

2970

75

90

76

6.8

150-125-250

350

60

2970

75.2

90

76

8.6

150-125-240

400

50

2970

72

90

76

9.8

150-125-270A

340

76

2970

89.5

110

78.6

8.5

150-125-250A

400

60

2970

88

110

74

9.8

150-125-280A

400

78

2970

106

132

80.6

9.8

150-125-280A

370

85

2970

106

132

80

9.7

250-200-500

500

80

1480

136

160

76

5


China WRY100-65-230 Thermal oil circulating pump wholesale

WRY100-65-230 Thermal oil circulating pump Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jiangsu Olymspan Thermal Energy Equipment Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 bjjsgy.com. All rights reserved.